Showerthought: I quit chasing intermittent squawks with a meter and started using the freeze spray trick
For years I'd chase intermittent faults with a multimeter and just poke at connectors until something showed up, and half the time I'd sign it off without really finding the gremlin. Last month a captain wrote up a flap position disagree on a King Air that only happened on climbout, and I finally tried freeze spray on the ADC connector pins at 34 degrees on the ramp in Wichita. Caught it in 20 minutes, the pin would open up cold. Wasted whole shifts on the same kind of thing before that. How many of you actually use temp cycling as a go-to, or do you still start with a meter?